Calibrator offers accurate calibration to -90C

An Ametek Calibration Instruments product story
Edited by the Engineeringtalk editorial team Dec 15, 2006

Ametek Calibration Instruments has introduced the new JOFRA ATC-125 ultra cooler which is the world's first dry block calibrator capable of reaching -90C

The calibrator also has a temperature range of 215 degrees C (-90 to 125C) Featuring patent applied for Free Piston Stirring Cooler (FPSC) technology for cooling the calibrator also has a special heating element, the ATC-125 that is stable and offers high accuracy.

The unit's fast heating and cooling makes a five point calibration up to five times quicker than with an equivalent liquid bath.

The calibrator can be used in a laboratory or factory environment.

Ideally suited to calibration applications in the pharmaceutical, food, food ingredients, hospital and marine industries, the ATC-125 can be used to perform fully automatic calibration routines without the need for a PC.

However the unit is also fully compatible with PC operation and is supplied complete with Jofracal calibration software.

The patent applied for FPSC is a Stirling heat pump in a lightweight (290g) compact unit that is up to six times more efficient than more commonly used Peltier coolers.

It uses a small amount of helium gas as the heat transport medium instead of conventional refrigerants such as CFCs, HFCs and Freon, making it environmentally friendly.

Since it is a dry block calibrator, no expensive or hazardous (flammable) liquids are used which may require special ventilation.

In addition, the entire temperature range can be reached without liquid changes.

In addition to the revolutionary new cooling technology, the ATC-125 utilises the proven ATC Series dual zone control technology to ensure precision calibration of sensors.

The lower zone in the system ensures optimum temperature distribution throughout the entire calibration zone, while the upper zone compensates for heat loss from the sensor under test.

High accuracy of + 0.3C with the internal reference sensor and + 0.06C with an external reference sensor can be achieved and there are no measuring errors due to thermoelectric effects or cable resistance.

In addition, the unit is supplied with mains power variance immunity (MVI) for improved temperature stability.

MVI removes stability problems by immediately identifying variations in the mains input voltage.

The MVI circuitry maintains a constant energy flow to the temperature block to provide a problem free calibration with a stability that the operator can trust.

The ATC-125 offers versatility for calibrating different diameter sensors and multiple sensors.

A variety of inserts are available ranging from a single hole insert for use with one sensor and the internal reference sensor to up to 24 or more sensors under test simultaneously with an external reference sensor.

Standard or custom sensor inserts are available with holes in both metric and imperial sizes.

Not what you're looking for? Search the site.

Back to top Back to top

Google Ads

 

Contact Ametek Calibration Instruments

Related Stories

Contact Ametek Calibration Instruments
Newsletter sign up

Request your free weekly copy of the Engineeringtalk email newsletter ...

Visit the Seaward Electronic web site

Browse by category

All suppliers A - Z

A Pro-talk Publication

A Pro-talk publication