Instead of relying on an external PC, the 10kV Delta3000 test set is controlled by an on-board version of Megger's PowerDB software package.

Megger's Delta3000 test set allows automated insulation power factor testing to be carried out without the inconvenience of having to link the tester to a laptop computerr.

This kind of testing is an invaluable aid to nondestructively assessing the condition of high-voltage electrical equipment such as transformers, circuit breakers and motors.

Instead of relying on an external PC, the 10kV Delta3000 test set is controlled by an on-board version of Megger's PowerDB software package, which also offers facilities for directly generating test reports, such as tables of contents and data sheets, as well as deficiency and comment reports.

Designed to be easy to use without the need for extensive hardware or software set up, the automated testing facilities offered by the Delta3000 test set reduce the time needed to carry out tests and virtually eliminates the risk of errors.

The operator interface is highly intuitive and supports user-configured test sheets and procedures.

A full qwerty keyboard complements the large built-in liquid crystal high-resolution colour display that shows the test results.

These include voltage, current, power (loss), power factor and capacitance.

The results can also be stored as an XML format file along with historical test data, making it easy to evaluate trends and to export the data to external software packages.

Data export is further facilitated by the instrument's USB memory stick support.

The Megger Delta3000 automated insulation power factor test set is a rugged portable unit that is ideal for on-site use.

It incorporates a tracking automatic interference suppression system that allows it to give reliable results even in the presence of severe electrostatic and electromagnetic interference, making it suitable for use in energised switchyards up 765kV.

For in-field calibration verification, the Delta3000 test set can be supplied with 100 and 1000pF reference capacitors.

For high-voltage turns-ratio testing, the test set can optionally be supplied with a 10nF TTR capacitor.

Additionally, as well as performing insulation power factor tests, the instrument can also be used for measuring the excitation current and inductance of transformer windings.

Find out more about this article. Request a brochure, download technical specifications and request samples here.

Not what you're looking for? Search the site.

Back to top Back to top

Contact Megger

Tel (UK)

Other Megger stories

Newsletter sign up

Request your free weekly copy of the Engineeringtalk email newsletter ...

Visit the Flir Systems web site

Browse by category

All suppliers A - Z

A Pro-talk Publication

A Pro-talk publication