Product category:
Testing and Calibration Services and Information
News Release from: AV Technology | Subject: AV Technology root cause analysis
Edited by the Engineeringtalk Editorial
Team on 26 March 2007
Analysis identifies recurring bearing
problem
AV Technology has a broad experience in providing structured and sustainable RCA solutions in industrial situations involving some form of persistent equipment failure.
Using root cause analysis (RCA), Stockport-based AV Technology (AVT) has identified the reasons behind a recurring bearing problem on a large electric motor operating at Solvay Interox' Warrington site AV Technology has a broad experience in providing structured and sustainable RCA solutions in industrial situations involving some form of persistent equipment failure
This article was originally published on Engineeringtalk on 11 Feb 2002 at 8.00am (UK)
Related stories
Predictive fatigue analysis pays dividends
AV Technology's Structural and Process Monitoring Division has extensive experience in the capture, analysis and interpretation of fatigue data across a broad spectrum of applications and industries.
Keeping Shell out of the heat
Out-sourced thermography consultancy has been used successfully to identify potential problem areas on three furnaces at Shell's Stanlow Refinery.
As independent consultants they have no "axe to grind" with any of the parties involved, thereby allowing them to look at the problem in an unbiased way.
The company's engineers have developed a blend of excellent observational skills, analytical capabilities and mechanical engineering skills, together with the wherewithal to use different external resources as necessary to arrive at a conclusion.
Coupled with this is a pragmatic understanding of tribological and metallurgical principles.
The 350kW, variable speed, inverter-driven motor drives a screw compressor providing process air for the Hydrogen Peroxide plant.
Failure of this motor would have resulted in a significant reduction in throughput.
AVT's Senior Engineer Andy Mellor explains how his company got to the root of the problem: "We were awarded a condition monitoring contract for the site and soon identified a developing bearing problem on the motor".
"A bearing change was scheduled for a production outage and we asked for the damaged bearing to be returned to us so we could conduct an RCA".
"Interviewing a range of staff, we found out that based on noise, bearings had been changed approximately every two years and the unreliability of the motor was well known".
"Inspection of the bearing revealed fluting on the outer race and darkening of the balls - a sure sign that an electric current was passing through the bearing during operation".
"A call to the motor manufacturer revealed that the bearing should have been insulated to prevent shaft voltages causing circulating currents to pass through the bearing and frame".
"The motor and plant were both mature - we believe that at some time in the past the insulated bearing fitted by the manufacturer was replaced by a motor repairer for a non-insulated type".
"Each time a replacement bearing was damaged through the passage of current another un-insulated bearing was fitted and the mistake had perpetuated". Request a free brochure from AV Technology ...
• AV Technology: contact details and other news
• Email this article to a colleague
• Register for the free Engineeringtalk email newsletter
• Engineeringtalk Home Page

