Product category:
Smaller-Sized PLCs
News Release from: TTi (Thurlby Thandar Instruments) | Subject: SIM960 analogue PID controller
Edited by the Engineeringtalk Editorial
Team on 13 March 2008
Analogue PID controller provides digital
control
The SIM960 analogue PID controller combines analogue signal handling with digital control, giving the user the best of both worlds.
TTi's SIM960 analogue PID controller is the latest addition to the SRS SIM (Small Instrumentation Modules) family The SIM is a robust, flexible platform in which up to eight high-performance instruments share the same compact mainframe and computer interface
This article was originally published on Engineeringtalk on 5 Mar 2001 at 8.00am (UK)
Related stories
Electronic loads offer high current capability
The Dynaload RBL Series of single-channel electronic loads offer an exceptionally high current rating of 1000A, and are ideal for the testing of large batteries and other DC power equipment.
Compact bench power supply provides 175W
The EX355, new from TTi (Thurlby Thandar Instruments), is a single-output laboratory DC power supply providing an output from 0 to 35V at 0 to 5A.
Unlike other modular systems, both front-panel and computer operation is possible.
The provides the functionality that users need while avoiding the cost of unnecessary features.
Users can configure their own systems from a selection of modules.
The SIM960 analogue PID controller combines analogue signal handling with digital control, giving the user the best of both worlds.
High-bandwidth (100kHz) control loops may be implemented without discrete time or quantisation artefacts.
The low-noise front end brings better performance to noise-sensitive applications such as laser power and wavelength stabilisation, cryogenics and scanning probe microscopy.
User-settable gain of up to 1000x gives greater flexibility, reducing the need for input preamplification.
The unit can be used together with the SIM921 AC resistance bridge to provide a flexible and cost-effective temperature control solution.
An internal ramp generator can control the voltage slew rate between predefined start and stop setpoints.
The output is clamped within upper and lower user limits to guard against system overload.
The conditional integration electronics provides anti-windup on the integrating capacitors, to faster recovery from saturation conditions.
The amplified error signal (P x e) and the output may be monitored with an LED bar display or via the millivolt resolution numeric display.
The 'setpoint' and 'measure' input signals can also be monitored on the numeric display.
Front-panel control enables easy modification of system parameters and convenient monitoring of input and output signals.
Power and serial communication are via a 15-pin D-sub connector which mates with the SIM900 mainframe.
All instrument parameters can be set and queried via the serial interface.
• TTi (Thurlby Thandar Instruments): contact details and other news
• Email this article to a colleague