DC drive technique eases maintenance
CP Automation's DC drives technique dispenses with the use of a 'keeper', which normally acts as a substitute for the armature in the servicing procedure.
CP Automation has released a service and repair technique for DC drives, attached to permanent magnet motors, that is set to make in-house re-setting of the serviced drive a thing of the past The technique dispenses with the use of a 'keeper', which normally acts as a substitute for the armature in the servicing procedure
This article was originally published on Engineeringtalk on 13 Nov 2007 at 8.00am (UK)
Related stories
Resistors are sized to work with drives
Alliance allows customers to buy inverter and resistor packages quickly and with confidence in the sizing and speciation of the equipment.
Motor miniaturised by new coil winding technology
Asaba Engineering has developed a high-efficiency coreless miniature DC motor for motion control applications.
Drive modules offer system integrators flexibility
The first multiple drive system on a common DC bus is now available as Modules from ABB, for use by system integrators, panelbuilders and OEMs.
Instead, the company de-magnetises the motor before repair and then re-magnetises it afterwards to the correct setting.
The company uses a set of specialist tools, including a magnetising cabinet, as well as intellectual property built up over decades in the drives industry to apply the new technique.
The reason that the settings on DC drives attached to motors that have been serviced or re-wound in their lifetime are often incorrect is that there is something to be borne in mind when repairing or servicing a DC permanent magnet motor.
The standard philosophy within the rewind industry is to remove the armature and replace it with a 'keeper'; to stop the levels of the magnets degrading.
However, older magnets and the material used to manufacture some newer magnets, will degrade while the armature is being removed and the keeper is being put in its place.
The same applies when the armature is put back in after repair or service.
The result is increased rev/min and lost torque, which may mean the motor draws more current, costing money and creating a greater environmental impact.
If the CPA process isn't used, an in-house engineer has to re-set the DC drive to cope with the changes to the motor.
As a result, all the systems in the plant eventually become unique and cease to be interchangeable.
The only solution is to de-magnetise the motor before repairing it and then re-magnetise it to the correct level afterwards, as CP Automation does.
The company derives the calculation for this from the speed and EMF (electro motive force) settings on the name plate of the motor.
"Plant managers want to swap equipment around in the event of a breakdown or maintenance issue", explained Tony Young, a director of CP Automation.
"However, they often find that the DC drives attached to permanent magnet motors on different production lines have different settings - making it hard to interchange things easily".
"Our solution means that that the settings will be exactly as specified on the name plate, meaning they can be swapped around easily".