The DAQP-Bridge-A from Dewetron has input isolation up to 350V RMS and offers a range of sensitivities down to 50mV/V and lowpass filters down to 10Hz.

The DAQP-Bridge-A from Dewetron has input isolation up to 350V RMS and offers a range of sensitivities down to 50mV/V and lowpass filters down to 10Hz.

The amplifier can be software configured for a range of excitation voltages and quarter to full bridge connection for 120ohm to 10kohm.

Auto input offset for zero adjustment can be performed via software or pushbutton and there is an internal shunt resistor quarter bridge calibration.

DC accuracy is +/- 0.1% full scale.