Oxygen analyser improves refinery performance

An Emerson Process Management product story
Edited by the Engineeringtalk editorial team Oct 9, 2006

Rosemount Analytical Oxymitters have replaced the previous sample extraction-based oxygen measurement system used on the catalyst regeneration unit at Total Raffinaderij Antwerpen, Belgium.

Rosemount Analytical Oxymitters from Emerson Process Management have replaced the previous sample extraction-based oxygen measurement system used on the catalyst regeneration unit at Total Raffinaderij Antwerpen, Belgium.

The more reliable readings from the Oxymitter have improved continuous catalyst regenerator (CCR) performance, helped the plant increase safety, and reduced the maintenance time and effort that needs to be allocated for critical catalytic reformer refinery operations.

The Total refinery in Antwerp is the second largest refinery in Europe, at 360,000 barrels per day, fed by pipeline from supertankers unloading at Rotterdam.

Catalytic reformers are used to improve the octane rating of the gasoline fractions produced.

Carbon is deposited on the catalyst during this process, so a portion of the catalyst is continuously extracted and routed to the CCR where the carbon is removed by burning it away in an oxidising atmosphere.

Measurement of oxygen in the regenerator is key to controlling the safety and rate of burn-off of this carbon, and maintaining regeneration efficiency.

Further, expensive platinum catalyst can become fused if the oxygen levels and bed temperatures are not maintained within set limits.

The Rosemount Analytical Oxymitter, being an in-situ probe where the sensor at the end of the probe is placed into the process, avoids the problems that were inherent with previous extractive analyser systems, where the sample lines tended to become plugged with catalyst fines and hydrochloric acid condensation.

Installations using the Oxymitter avoid the costs and downtime caused by such plugging, and operators can run their regenerator control system continuously, with fewer maintenance interruptions.

Further, a reliable measurement of oxygen level gives the operator the confidence needed to run the CCR unit at the optimum rate of regeneration.

The Oxymitter has been in service for seven months and has performed with accuracy and reliability.

This excellent product performance was expected since many other Oxymitter units have been installed around the plant on flue gas analysis systems.

In this application, the pressurisation option on the Oxymitter is used to compensate for the 2bar operating pressure in the regenerator.

The response and assistance provided by Emerson during installation, was much appreciated.

With the Hart diagnostic functionality, the instrument engineers within the Total refinery can use the predictive maintenance information provided, and can thereby increase overall reliability.

A second Oxymitter unit will be installed soon.

The advanced Emerson technology in the Rosemount Analytical Oxymitter, a zirconia based oxygen sensor, is recognised worldwide, and has become the standard for efficient monitoring of oxygen levels in catalyst regenerators on many petrochemical plants, including fluidised catalytic cracking unit (FCCU) regenerators.

Not what you're looking for? Search the site.

Back to top Back to top

Contact Emerson Process Management

Tel (UK) 0870 240 1978

Request information

Other Emerson Process Management stories

Newsletter sign up

Request your free weekly copy of the Engineeringtalk email newsletter ...

Visit the Magnetrol International web site
A Pro-talk Publication

A Pro-talk publication