Monitoring system protects gearboxes
Vibration monitor of geaboxes allows early detection of damage, preventing serious downtime.
By providing online condition monitoring and training, FAG Industrial Services is helping manufacturers in the cement, mining and quarrying industries to eliminate unscheduled shutdowns and avoid costly repairs to transmission gears, gearboxes and other critical rotating plant and machinery By investing in online condition monitoring systems to automatically detect early damage to gearboxes, cement manufacturer Spenner Zement has prevented unplanned downtime and avoided costly repairs to transmission gears and gearboxes at its cement mill in Erwitte, Germany
This article was originally published on Engineeringtalk on 27 Mar 2008 at 8.00am (UK)
Related stories
Condition monitoring pays of for aluminium worker
A manufacturer of rolled aluminium products is saving around Eur 200,000 per year by monitoring the condition of critical machine components on its rolling mill machinery.
Precision bearings keep hydraulic systems running
Hydraulic drives and pumps require precision bearings and seals that are reliable, efficient and able to withstand the most demanding operating conditions.
Spenner Zement produces a range of cement, lime and dry mortar products.
The company also develops disposal concepts for different industry sectors whose waste products can be used for secondary raw materials and fuel.
The company operates several cement mills (tube mills) at its Erwitte site.
Back in 2002, Spenner faced a production problem on one of its cement mills at Erwitte.
One of the tube mills had to be shut down for three weeks because of damage to a gearbox that was driving the mill.
Further reading
Overview covers full linear range
Guide presents a complete overview of linear bearings and guidance systems available from precision bearings manufacturer Schaeffler UK.
Vibration sensor spots bearing damage early
FAG Detector III is used for the early detection of damage in rotating machine elements such as rolling bearings.
Monorail guidance systems explained
Guide to guidance systems and accessories includes both linear recirculating roller bearing and ball bearing guideway assemblies, as well as complete linear guidance systems.
At the time, the three-stage gearbox was being monitored by a temperature sensor, which failed to give Spenner's maintenance team enough warning of damage to the gearbox.
The gearbox damage and subsequent failure not only resulted in three weeks of unplanned downtime on the tube mill, but also resulted in costly repairs, which included a completely new shaft and refurbishment of parts of the gearbox housing.
Spenner then called in experts from FAG Industrial Services (F'IS), the maintenance and condition monitoring company within the Schaeffler group, to help eliminate any future unplanned stoppages to its tube mill.
F'IS recommended its online vibration monitoring system, FAG DTECT X1, along with four, permanently-installed sensors positioned on the main gearbox and reduction gear.
Three sensors were installed on the main gearbox to monitor the gear bearings and gear mesh, with one sensor installed at the reduction gear to monitor gear rim and pinion condition.
In addition to installing the FAG DTECT X1 system and sensors, F'IS also provided three months' vibration monitoring training.
Spenner maintenance engineers were trained to analyse the condition monitoring data and are now capable of monitoring and analysing the data on their own.
In 2004, around 18 months after installing the new condition monitoring system, the FAG DTECT X1 system detected damage to the gear teeth in the gear mesh.
Initially, yellow alarms were displayed on the system, followed by temporary red alarms, indicating potential serious damage.
Visual inspection from Spenner engineers confirmed that tooth damage had occurred in the second stage gears.
The gearbox was subsequently replaced during the next scheduled shutdown period, without causing any disruption to production.
Had the tooth damage been left undetected, damage to other parts of the gearbox may have occurred, causing costly repairs and further delays to production.
In 2006, Spenner equipped another two of its cement tube mills at Erwitte with FAG DTECT X1 systems.
Five sensors are installed on each system, with three monitoring the vibration on the rolling bearings and the gear teeth.
The other two sensors monitor vibration at the reduction gear bearings, girth gear and pinion.
All data is transmitted directly to Spenner's central control room at the plant, automatically triggering an alarm if deviations from pre-set parameters are detected.
Although several Spenner engineers are now fully trained to analyse the collected data, when initial signs of complex problems are detected, data can be emailed direct to F'IS experts who can carry out in-depth analysis on the data and recommend the appropriate action to be taken.
By analysing the data sent to them, F'IS experts not only detect the problem, but also can pinpoint the damaged component.
For example, the type of damage and how quickly the damage progresses, provides valuable clues for maintenance planning teams.
Thanks to early detection, special replacement parts can be purchased in time and replacement can be carried out during routine, planned maintenance intervals.
Other manufacturers are also benefiting from the maintenance and condition monitoring expertise of F'IS.
German company MHI (Mitteldeusche Hartstein Industrie), a natural stone mining company and leading producer of asphalt and concrete based in Hanau, Germany recently set up a central workshop for its 16 plants, which is to become the Condition Monitoring (CM) Centre of Excellence for the group.
Up to that point, vibration analysis had not been used at the plants and F'IS was invited to the CM group to present its expertise in this area.
F'IS' initial meeting with the management team and maintenance staff at MHI included a presentation of its complete range of condition monitoring products and services.
A contract was concluded covering a two-year vibration monitoring training programme for MHI employees.
This training included fundamentals; FAG Detector II (handheld vibration monitor) product training; regular on site support from F'IS experts on offline measuring projects at the plant; and data analysis support from F'IS both on site and via e-services.
During this two-year contract, F'IS was commissioned to conduct a plant-wide check, which involved commercial, organisational and structural analysis of the operational procedures at MHI.
Weak points were determined and improvement suggestions developed.
Belt conveyor drives, vibrating screens and crushers at MHI's Gross-Bieberau plant are now being monitored.
A total of 70 measuring points are being monitored, with permanent sensors installed at 20 of these points.
Even a defect in a small bearing can cause the complete destruction of a gearbox (worth Eur 50,000) driving this plant and machinery.
Production losses due to gearbox failure cost Eur 500 per hour and any unscheduled downtime means repair work that takes at least one to two days to complete. Request a free brochure from Schaeffler (UK) ...