Safety controller links with Mitsubishi
PLC

Request your FREE weekly copy of the Engineeringtalk email newsletter. News about Machine Safety Monitoring and Control and more every issue. Click here for details.

Controls and Drives has used a CC-Link module to connect a PNOZmulti safety controller with a Mitsubishi Q-series high-end modular PLC.

Controls and Drives (CDL), part of the BPX Group, is one of the authorised Pilz distributors in the UK, and it is also a Centre of Technical Excellence for Mitsubishi Automation When Pilz launched the PNOZmulti software-configurable modular safety controller and the family of communications modules that go with it, CDL was understandably keen to try using the CC-Link module to connect a PNOZmulti safety controller with a Mitsubishi Q-series high-end modular PLC

The results were impressive.

A PNOZmulti m1p base unit with a PNOZ mc7p CC-Link communications module was connected with a Pilz PITestop emergency stop switch and a Pilz PSEN 1.1p-10 noncontact safety switch.

Using a standard CC-Link cable plugged into the CC-Link module on the PNOZmulti, the safety equipment was connected to the Mitsubishi Q-series PLC via a Mitsubishi QJ61BT11 CC-Link network card.

This CC-Link card was configured as a master; the module on the PNOZmulti operates as a slave.

Configuration of the PNOZmulti was performed using the PNOZmulti Configurator software running on a laptop PC, with the configuration data transferred to the PNOZmulti via a serial cable (no safety-related data can be transferred via the CC-Link cable).

Mitsubishi's GX Developer software was used to write ladder code for the Q-series PLC and the QJ61BT11 CC-Link network card.

In addition to the hardware described above, a touchscreen HMI (human-machine interface) was connected to the Q-series PLC and configured with E Designer such that the safety data from the PNOZmulti could be monitored.

In other words, the status of the safety circuit could be viewed on-screen in real-time.

Latest job opportunities

Multi Skilled Maintenance Engineer, Maintenance Engineer
Maintenance Engineer (FOOD/FMCG)
Job Title: Multi Skilled Maintenance Engineer, Maintenance Engineer
Area: Buckinghamshire, Bedfordshire, London, Middlesex, Hertfordshire, Buckinghamshire, Berkshire, Essex, Kent, Surrey, South East
Salary: ...

Electrical, Mechanical, Maintenance Engineer
Mechanical Fitter, Diesel Fitter, Mechanical Technician, Maintenance Engineer X4
Job Title: Electrical, Mechanical, Maintenance Engineer
Area: East London, Essex, Bedfordshire, Hertfordshire, Buckinghamshire, London, Berkshire, Middlesex,...

(Embedded) Electronics Design Engineers - Graduates to Senior
(Embedded) Electronics Design Engineers - Avon Ongoing business growth at this worl leading company has created a number of challenging and rewarding career opportunities to appeal to exceptional Electronics Design Engineers with varying levels of...

Furthermore, the HMI was configured to incorporate a reset switch so that a reset signal could be initiated at the HMI and sent via the Q-series PLC and CC-Link fieldbus to the PNOZmulti.

Alternatively, a conventional reset switch could have been connected directly to the PLC and its status monitored via the HMI concurrently with the safety-related data from the PNOZmulti.

This exercise clearly demonstrates how easy it is to incorporate a Pilz PNOZmulti safety controller within an automation system based on a Mitsubishi Q-series PLC and a CC-Link industrial fieldbus.

Being able to monitor the safety functions so accurately on a machine's HMI would enable the causes of stoppages to be identified far more quickly so that downtime can be minimised.

In addition, almost no extra wiring would be required, as the CC-Link cable would already be in place around the machine to serve the conventional I/O.

Of course, once the data about the status of the safety components are available within the PLC, the machine builder is not limited to just displaying them on an HMI; almost anything could be done with them to help minimise downtime, log events, or feed into a machine availability analysis system, for example.

For those who are concerned about the apparent mixing of safety and nonsafety data, they can rest assured that there is absolutely no way that the PNOZmulti configuration can be altered by data sent via the CC-Link cable, and the monitoring of safety status data is effectively no different from hard-wiring a PLC to the auxiliary contacts on conventional electromechanical safety relays.

Matt Wills, the Technical Applications Engineer at CDL who ran the trials, comments: "We wondered how easy it would be to link the PNOZmulti with the Q-series, and the answer was 'very'".

"In fact it worked first time and we were astonished at how simple it was to access data that can make such a big difference to a plant's uptime".

Lee Clarke, the Sales Manager at CDL, adds: "We believe there is a significant niche market for this type of arrangement".

"Anyone building a medium-complexity machine with a Mitsubishi Q-series PLC could save money anyway by using a PNOZmulti rather than safety relays, and then you effectively get the diagnostics for free".

"Of course the same result can also be achieved using an old A series PLC or a current FX PLC".

"But to try and get this level of monitoring using traditional hard-wiring would simply be unfeasible for most applications".

In addition to the CC-Link communications module, Pilz also offers versions for use with Profibus DP, DeviceNet, Interbus or CANopen.

Similar remote monitoring of safety-related data can therefore be achieved with automation systems using these other fieldbus protocols.

Pilz Automation Technology: contact details and other news