Visit the Stemmer Imaging web site

Stemmer releases Piranha HS 12k and Xcelera-HS

A Stemmer Imaging product story
Edited by the Engineeringtalk editorial team Mar 11, 2010

Stemmer Imaging is offering the first products that utilise the HSLink machine-vision connectivity interface pioneered by Dalsa.

These are the new Piranha HS 12k 90kHz linescan camera and the Xcelera-HS PX8 frame grabber.

The new HSLink interface from Dalsa has been designed in co-operation with the Camera Link 2 subcommittee to meet the needs of all machine-vision applications.

It carries image data, configuration data and low jitter, real-time triggering signals over a simple network topology supporting cameras, intermediate devices and frame grabbers.

It combines the key strengths of Camera Link with new features and functions.

HSLink is designed from a system point of view, ensuring the ability to create low-cost cameras and frame grabbers, while meeting the ease of use, flexibility and data reliability demanded by end customers.

HSLink delivers scalable bandwidth in 300 megabyte/second steps, from 300 to 6000 megabytes/second while using globally available, off-the-shelf components.

The Piranha HS 12k high-sensitivity linescan camera heralds a breakthrough in time delay and integration digital-imaging technology and is available in Camera Link Full or the new HSLink output formats.

The Piranha HS 12k camera has a maximum line rate of 90kHz and 12,000 pixel resolution.

It can deliver more than 1.2 gigapixel throughput.

It is available in 1200 or 640 megapixels/second versions so that OEMs can select the model that best fits their requirements.

All models are capable of bidirectional operation with up to 256 stages of selectability, while preventing overexposure with antiblooming features.

The Xcelera-HS PX8 Series of frame grabbers supports the Piranha HS 12k camera and utilises the PCI Express (PCIe) platform to provide simultaneous image acquisition and transfer with little intervention from the host CPU.

For machine-vision OEMs, the Xcelera-HS PX8 combines the HSLink interface with onboard pre-processing functions such as shading correction and Bayer decoding.

The Xcelera-HS PX8 delivers an outstanding image-acquisition bandwidth of 1.8GByte/sec and host transfer bandwidth of 2GByte/s over multiple-lane PCI Express implementations.

The Xcelera-HS PX8 has been built within Dalsa's Trigger-to-Image Reliability technology framework to guarantee the reliability of the image-acquisition system.

The new frame grabbers are supported by Dalsa's Sapera Essential standard machine-vision software toolkit for the design and development of high-performance machine-vision applications.

Find out more about this article. Request a brochure, download technical specifications and request samples here.

Not what you're looking for? Search the site.

Back to top Back to top

MyTalk

Add to My Alerts

Company Stemmer Imaging


Category Vision and Colour Sensors

Contact Stemmer Imaging

Tel +44 1252 780 000

Other Stemmer Imaging stories

Newsletter sign up

Request your free weekly copy of the Engineeringtalk email newsletter ...

Visit the Stemmer Imaging web site
A Pro-talk Publication

A Pro-talk publication