Bypasses alow safe UPS maintenance

A Riello UPS product story
Edited by the Engineeringtalk editorial team Mar 11, 2002

Advance-Galatrek has introduced its latest wall mounted WBS range of maintenance bypasses for uninterruptible power systems (UPSs).

Advance-Galatrek has introduced its latest wall mounted WBS range of maintenance bypasses for uninterruptible power systems (UPSs).

These units allow the safe maintenance of a UPS, entirely without disruption or interruption to the supported load, as well as offering a host of additional safety and convenience features.

The WBS maintenance bypass range can be specified either with single or three phase input and single or three phase output.

Units can be supplied suitable for UPS capacities between up to 120kVA.

The latest Advance-Galatrek WBS maintenance bypasses features a three position lockable make-before-break transfer switch.

When in the normal position, the load is powered directly from the UPS, as usual.

When the transfer switch is placed in the second position, the raw mains supply is used to power the load, at the same time as the UPS is connected to the mains supply.

The advantage of this particular configuration is that it allows the UPS to be safely tested, without causing damage to the load, or potential disruption to the power supply.

When the transfer switch is placed in the third bypass position, the load is connected to the mains supply.

The make-before-break capability means that the load is connected to the selected power source before the alternative source is disconnected, and vice versa.

In practice, this eliminates any interruptions to the power supply, no matter how brief.

When in the normal position, the load is safely powered by the UPS.

However, when in the other positions, and in order to guarantee the ultimate safety for sensitive and mission critical loads, Advance-Galatrek recommends the addition of a transient voltage surge suppressor (TVSS) from its StrikeSafe range.

The TVSS modules can be installed either within the WBS bypass itself, or before the bypass, as a separate transient protection unit (TPU).

For the ultimate protection for mission critical applications, Advance-Galatrek advocates the use of a power conditioner in the bypass supply.

Models within its GT range features a ferroresonant transformer, which provides galvanic isolation.

This enables a complete physical separation between the mains supply and the load, with the added bonus of full time power conditioning.

This feature guarantees that the mains supply will be free of spikes and electrical noise, while sags, surges and brownouts will be corrected within the unit.

The GT power conditioner is supplied as a separate floor standing unit.

Not what you're looking for? Search the site.

Back to top Back to top

Google Ads

 

Contact Riello UPS

Related Stories

Contact Riello UPS

 

Newsletter sign up

Request your free weekly copy of the Engineeringtalk email newsletter ...

Visit the Smartscan web site

Articles by product category

All suppliers A - Z

A Pro-talk Publication

A Pro-talk publication