Product category:
Electrical and Electronic Testing and PAT Equipment
News Release from: Tektronix | Subject: TDS210 digital oscilloscope
Edited by the Engineeringtalk Editorial
Team on 03 July 2000
DSO speeds tests on aircraft emergency
slides
A Tektronix digital oscilloscope is playing a key part in tests designed to ensure the reliable deployment of the emergency passenger escape slides used on modern airliners.
A Tektronix digital oscilloscope is playing a key part in tests designed to ensure the reliable deployment of the emergency passenger escape slides used on modern airliners The TDS210 instrument, supplied by Tektronix distributor Arrow Catalogue, is being used by Stansted Airport based AEM Limited to monitor critical performance characteristics of the discharge valves used to inflate the slides
This article was originally published on Engineeringtalk on 23 Feb 2001 at 8.00am (UK)
Related stories
Portable field measurements in wireless networks
Tektronix has announced a new compact, modular instrument, the NetTek base station field tool, designed to simplify routine field installation and maintenance measurement tasks in wireless networks.
It's the world's fastest real-time oscilloscope
Tektronix has announced groundbreaking 4-Gigahertz real-time performance in a new family of digital phosphor oscilloscopes (DPOs).
AEM is a specialist aviation service supplier with a division responsible for overhauling and servicing safety equipment.
Testing emergency slides is an important part of its operation, and one in which 100% accuracy and reliability is essential.
When operated - normally by a pull cord - the slide has to inflate in a controlled manner.
If inflation occurs too quickly, it can damage the slide or cause it to inflate within the aircraft and block the escape route.
Hence the gas discharge valve has to release the pressurised gas over a set period of time - typically around four seconds - allowing the slide to unfold smoothly and assume its final shape without any discontinuities.
Further reading
The scope for automotive electronic diagnostics
Frank Massey of Fuel Injection Services and Christine Rickett of Tektronix look at the instrumentation in use for automotive electronic diagnostics
10 Gb/s SONET/SDH testing in the field
Tektronix has introduced a portable version of its OTS9000 Optical Test System which provides field testing of new high-speed, 10 gigabits per second optical networks
Innovative technology for optical comms test
Tektronix has introduced Digital Phase Analysis (DPA), an innovative, best-in-market jitter and synchronisation testing technology for telecommunications networks.
A wide variety of slides are used on different types of aircraft, and it is important for companies like AEM to build up a 'library' of the ideal characteristic profiles of each type.
In fact, CAA/FAA regulations require records of such tests to be kept as hard copy and filed for at least five years.
Previously, AEM achieved this by linking a chart recorder to a pressure transducer.
Latest job opportunities
(Embedded) Electronics Design Engineers - Graduates to Senior
(Embedded) Electronics Design Engineers - Avon Ongoing business growth at this worl leading company has created a number of challenging and rewarding career opportunities to appeal to exceptional Electronics Design Engineers with varying levels of...
(DEM) Depot Engineering Manager Technician
(DEM) Depot Engineering Manager Technician
£31,000 - £40,000 dependant on experience
Exeter and Bristol
This senior role will see you ensure that our Depot continues to meet engineering standards, as well as others - including...
Field Service Engineer, Field Service, Service Engineer (Medical).
Field Service Engineer, Medical Field Service Engineer
Job Title: Field Service Engineer, Field Service, Service Engineer (Medical).
Area: Hampshire, Berkshire, Middlesex, Buckinghamshire, Hertfordshire, London, South East.
Salary:...
The test engineer would start the recorder when the pull cord was activated, and hope that the discharge plot would be completed within the recorder's sweep time.
This operation involved a number of potential problems, largely because there was no guarantee that recording would happen reliably during the critical period of discharge.
In addition, amplitude variations could cause the pen to jump off the paper.
Interpretation of the results was also time-consuming, requiring measurements of the chart readout and calculations on the resulting figures.
When the existing chart recorder was nearing the end of its life, AEM approached Arrow Catalogue for a replacement.
However, Arrow's Manager for Instruments and Tools, Robin Rayner, pointed out to them that they could carry out the job more efficiently, and at lower cost, by using a digital oscilloscope linked with a printer via its built-in digital interface.
Because Arrow's catalogue contains over 1200 different test instruments including 64 oscilloscope models, the company is well placed to give independent advice of this type.
The Tektronix TDS210 was chosen because it offered the necessary performance not only to monitor the gas discharge but also to trigger automatically when the pull cord was operated - and to measure the pull force and automatically plot it on the same curve.
The instrument's compact size and light weight were added bonuses, allowing it to be easily fitted into the existing test bench set-up.
As a final benefit, the total cost of the oscilloscope and printer combined was less than half that of the replacement chart recorder.
The instrument is used in conjunction with a Druck pressure transducer and a MecMesin portable force indicator.
The built-in signal processing within the oscilloscope converts the analogue signals from the transducers into direct readings in engineering units on the LCD screen and printer.
Normally, the oscilloscope is arranged to trigger when the pull force reaches a certain value (typically ten pounds), so that it captures the entire discharge process with no wasted time at the start.
The oscilloscope and printer are set up to produce a standard plot at 10 bar/cm, compatible with the reporting format previously used and capable of being pasted directly into the final test reports.
Comment's Arrow's Robin Rayner: 'The engineers at AEM are highly delighted with the Tektronix oscilloscope, which is allowing them to run their tests faster, more easily and more efficiently at a fraction of the price. Request a free brochure from Tektronix ...
They have already expressed an interest in buying further Tektronix products as a result.'.
• Tektronix: contact details and other news
• Email this article to a colleague
• Register for the free Engineeringtalk email newsletter