Safe sampling without stopping

A Tyco Flow Controls product story
Edited by the Engineeringtalk editorial team Oct 24, 2003

The problem of obtaining process samples from reactor vessels without requiring process shutdown can be solved using the PV vessel-sampling device from Neotecha.

The problem of obtaining process samples from reactor vessels without requiring process shutdown can be solved using the PV vessel-sampling device from Neotecha.

The sampling device is designed specifically to lift samples from reactor vessels under process conditions, producing more accurate results.

The PV is capable of extracting even highly corrosive or toxic media, while its design eliminates the possibility of any hazardous liquid or gaseous release to atmosphere.

The PV's vacuum operation lifts liquid from the reactor through a heavy duty PFA suction hose, which is located within the dip tube inside the vessel.

The media flows upward into the sight glass through a ball valve, which can be supplied in a dead-spot free C-ball design that prevents retention of residual media after sampling is completed.

A PTFE hollow ball inside the sight glass rests on the top of the rising sampled liquid, and interrupts the vacuum when the sight glass is full, preventing over-extraction or liquid entering the vacuum line.

Once in the sight glass, the sample passes at atmospheric pressure through a transfer device to the sample bottle for testing.

The PV is suitable for either manual or automatic operation.

Neotecha also offers the option of a failsafe bottle-sensing device.

The device senses if the bottle has been correctly attached before undertaking sample transfer, eliminating the possibility of accidental spillage.

For periodic pH measurement, a probe adapter can be fitted.

Liquid can be simply drawn from the vessel into the sight glass, tested, and replaced into the reactor without needing to expose the pH probe to potentially corrosive substances for long periods.

The PV is available either in stainless steel or lined, with wetted parts in PFA, PTFE or glass.

It is pressure rated to 10bar, and temperature rated to +200degC.

PV is available with a sample volume of either 150, 250, 500 or 1000ml.

Neotecha products are available from Tyco Valves and Controls.

Not what you're looking for? Search the site.

Back to top Back to top

Contact Tyco Flow Controls

Related Stories

Contact Tyco Flow Controls

 

Newsletter sign up

Request your free weekly copy of the Engineeringtalk email newsletter ...

Visit the James Walker and Co web site

Search by company

A Pro-talk Publication

A Pro-talk publication