Categories
- Consultancy and Services (876)
- Machine Building (4,310)
- Engineering Design Software (5,998)
- Drives, Motors and Controls (3,174)
- Small Mechanical Components, Joining, Tools (1,896)
- Control and Instrumentation (4,881)
- Monitoring, Measurement and Quality (5,196)
- Electrical and Electronic Equipment Design (4,015)
- Materials and Processing (2,829)
- Engineering Industry News, Resources (6,045)
- Powertrain Design (3,420)
- Capital Equipment (3,259)
- Sensors (6,677)
- Valves, Pumps, Process Hardware (3,498)
Meters monitor on/off run time
M series elapsed time or hours-run meters are available for AC and DC power applications and measure time in increments of 0.01 hour up to 99999.99 hours.
New elapsed time meters (ETM) or hours-run meters from Crompton Instruments Business Unit, part of Tyco Electronics - Energy Products division, monitor "on/run" time of machines in production plants as well as equipment power supplies, allowing the user to effectively control production efficiency, cost estimation and service period monitoring for preventative maintenance.
M series elapsed time or hours-run meters are available for AC and DC power applications and measure time in increments of 0.01 hour up to 99999.99 hours, after which the meter automatically resets to zero.
To prevent accidental resetting, meters cannot be reset manually before reaching 99999.99 hours.
AC power models within the M series of meters are available in three different versions for applications featuring 100V up to 125V AC, 200V up to 250V AC and 380V up to 440V AC and are designed for an operating temperature range from -25C up to 80C.
Three different DC power variants cover power ranges of 0.5VA (6V up to 30V DC), 1VA (10V up to 80V DC) and 1.5VA (110V DC) and feature an operating temperature range from -20C up to 70C.
All devices benefit from IP40 protection.
Not what you're looking for? Search the site.
Tel (UK)
-
Digital metering supports Ethernet communication
The Integra 1630 DMS with Ethernet module acts as a BACnet/IP server device and may be queried by a BACnet/IP client device which conforms to the BACnet/IP protocol. -
Digital meter gets the measure of power
System provides programmable measurement, display and communication of up to 50 major electrical and power quality parameters, including true RMS system values. -
Transfer switch monitors AC signal
In the event of a mains voltage failure of any phase, the remote start relay output is energised and the unit automatically transfers the load from the mains to the generator. -
Ethernet communications added to metering system
The Integra 1630 DMS with Ethernet module acts as a Modbus slave device and may be queried by a Modbus master device conforming to the Modbus TCP protocol. -
Current transformers handle 60 to 2500A
Tyco Electronics' Crompton Instruments current transformers are easily and quickly installed where conventional foot/busbar mount devices are not practical.
